Skip to Content
Fluke 381 Remote Display True RMS AC/DC Clamp Meter with iFlex®

Price:

$ 817.19


Fluke FLUKE- 325 400A AC/DC TRUE RMS CLAMP METER W/TEMP (AMERICAS & EMEA)
Fluke FLUKE- 325 400A AC/DC TRUE RMS CLAMP METER W/TEMP (AMERICAS & EMEA)
$ 394.19
$ 437.99 (10% OFF)
Fluke 107 Esp Fluke 107 CAT III 600V Digital Multimeter Esp (Fluke 107)
Fluke 107 Esp Fluke 107 CAT III 600V Digital Multimeter Esp (Fluke 107)
$ 144.89
$ 160.99 (10% OFF)

Fluke 381 Remote Display True RMS AC/DC Clamp Meter with iFlex®

https://www.etisupply.com/web/image/product.template/24073/image_1920?unique=443a372

SKU: 5065875 | 381

  • Wireless technology allows the display to be carried up to 30 ft. away from the point of measurement with measurement accuracy
  • Removable magnetic display can be mounted where it is easily seen
  • iFlex® Flexible Current Probe expands the measurement range to 2500 A AC
  • CAT IV 600 V, CAT III 1000 V

What's in the box:

  • 18-inch iFlex ® flexible current probe
  • Coated instruction card
  • Safety information sheet
  • Soft carrying case
  • TL75 test leads
  • Five AA Alkaline batteries

$ 817.19 817.191 USD $ 907.99

Not Available For Sale

($ 0.00 / Units)

  • Brand

This combination does not exist.

True RMS Clamp Meters CAT III 1000 V CAT IV 600 V Fluke

 
Terms and Conditions

Product images shown are for illustration purposes only and may not be an exact representation of the product.

Fluke

381

Fluke 381 Remote Display True RMS AC/DC Clamp Meter with iFlex®

Details

What once took two people, now takes one

Now one technician can do jobs that would otherwise require two people. Clamp the Fluke 381 around a conductor, remove the display and walk across the room to operate controls or remove protective equipment, all while watching real-time readings.

The iFlex® Flexible Current Probe (included) expands the measurement range to 2500 A AC while providing increased display flexibility. With a cord that runs 6 feet, you can finally measure those tight spaces, awkward sized conductors and disorganized wires.

Other key features

  • Integrated low pass filter and state-of-the-art signal processing allows for use in noisy electrical environments while providing stable readings
  • Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
  • Ergonomic design fits in your hand and can be used while wearing protective equipment
  • Radio transmitter automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
  • Three-year warranty

Safety Conformance: IEC/EN 61010-1:2001, 1000V CAT III, 600V CAT IV

What's in the box:

  • 381 Remote Display Clamp Meter
  • (1 pair) TL75 test leads
  • (1 pair) AC175 alligator clips
  • 18-inch iFlex®flexible current probe
  • Soft carrying case

Key Features

  • Wireless technology allows the display to be carried up to 30 ft. away from the point of measurement with measurement accuracy
  • Removable magnetic display can be mounted where it is easily seen
  • iFlex® Flexible Current Probe expands the measurement range to 2500 A AC
  • CAT IV 600 V, CAT III 1000 V

Specifications

Electrical Specifications
AC Current via Jaw
Range999.9 A
Resolution0.1 A
Accuracy2% ± 5 digits (10-100 Hz)
5% ± 5 digits (100-500 Hz)
Crest Factor (50/60 Hz)3 @ 500 A
2.5 @ 600 A
1.42 @ 1000 A
Add 2% for C.F. > 2
AC Current via Flexible Current Probe
Range999.9 A / 2500 A (45 Hz – 500 Hz)
Resolution0.1 A / 1 A
Accuracy3% ± 5 digits
Crest Factor (50/60 Hz)3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Position Sensitivity
Distance from Optimum
i2500-10 Flexi2500-18 FlexError
A0.5 in (12.7 mm)1.4 in (35.6 mm)±0.5%
B0.8 in (20.3 mm)2.0 in (50.8 mm)±1.0%
C1.4 in (35.6 mm)2.5 in (63.5 mm)±2.0%
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range999.9 A
Resolution0.1 A
Accuracy2% ± 5 digits
AC Voltage
Range600 V /1000 V
Resolution0.1 V / 1 V
Accuracy1.5% ± 5 digits (20 – 500 Hz)
DC Voltage
Range600.0 V /1000 V
Resolution0.1 V / 1 V
Accuracy1% ± 5 digits
Frequency – Via Jaw
Range5.0 – 500.0 Hz
Resolution0.1 Hz
Accuracy0.5% ± 5 digits
Trigger Level5 – 10 Hz, ≥ 10 A
10 – 100 Hz, ≥ 5 A
100 – 500 Hz, ≥ 10 A
Frequency via Flexible Current Probe
Range5.0 to 500.0 Hz
Resolution0.1 Hz
Accuracy0.5% ± 5 digits
Trigger Level5 to 20 Hz, ≥ 25 A
20 to 100 Hz, ≥ 20 A
100 to 500 Hz, ≥ 25 A
Resistance
Range600 Ω/6 kΩ/60 kΩ
Resolution0.1 Ω/1 Ω/10 Ω
Accuracy1% ± 5 digits
Mechanical Specifications
Size (L x W x H)277 x 88 x 43 mm (55 mm for remote unit)
Weight350 g
Jaw Opening34 mm
Flexible Current Probe Diameter7.5 mm
Flexible Current Probe Cable Length
(head to electronics connector)
1.8 m
Environmental Specifications
Operating Temperature-10°C to +50°C
Storage Temperature-40°C to +60°C
Operating HumidityNon condensing (< 10°C)
≤ 90% RH (at 10°C to 30°C)
≤ 75% RH (at 30°C to 40°C)
≤ 45% RH (at 40°C to 50°C)
(Without Condensation)
Operating Altitude2,000 meters
Storage Altitude12,000 meters
EMI, RFI, EMC, RFEN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006
ETSI EN 300 489 V1.8.1:2008
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID: T68-F381
RSS-210 IC: 6627A-F381
Temperature CoefficientsAdd 0.1 x specified accuracy for each degree C above 28°C or below 18°C
Wireless Frequency2.4 GHz ISM Band 10 meter range
Safety ComplianceANSI/ISA S82.02.01:2004
CAN/CSA-C22.2 No. 61010-1-04
IEC/EN 61010-1:2001 to 1000V CAT III, 600V CAT IV.
Double Insulation ClearancePer IEC 61010-2-032
Double Insulation CreepagePer IEC 61010-1
Agency Approvals

Additional specifications

  • Part #: 5065875
  • UPC: 0 95969 53748 3
  • AC current via jaw: 999.9 A; 2% ±5 digits (10-100 Hz), 5% ±5 digits (100-500 Hz)
  • AC current via flexible probe: 999.9 A / 2500 A (45 Hz to 500 Hz); 3% ±5 digits
  • DC current: 999.9 A; 2% ±5 digits
  • AC voltage: 600 V / 1000 V; 1.5% ±5 digits (20-500 Hz)
  • DC voltage: 600.0 V / 1000 V; 1% ±5 digits
  • Frequency via jaw: 5.0 to 500.0 Hz; 0.5% ±5 digits
  • Resistance: 600 Ω / 6 kΩ / 60 kΩ; 1% ±5 digits
  • Weight: 350 g (0.77 lb)
  • Warranty: 3 years

Additional Information



Brand Fluke
381-Calibration-Manual-FLK_5065875.pdf
Download
381-Calibration-Manual-Supplement-FLK_5065875.pdf
Download
381-Quick-Reference-Guide-FLK_5065875.pdf
Download
381-Safety-Sheet-FLK_5065875.pdf
Download
381-Users-Manual-FLK_5065875.pdf
Download
Fluke-381-Remote-Display-True-rms-AC-DC-Clamp-Meter-with-iFlex-Datasheet-FLK_5065875.pdf
Download
i2500-36-i2500-18-i2500-10-Quick-Reference-Guide-FLK_5065875.pdf
Download