Skip to Content
Kyoritsu 6514BT Digital Multifunction Tester with Bluetooth_EVSE *NEW

Price:

2,483.00


Central Tools 3C301 – STORM™ Digital Caliper, Range: 0-6”/0-150mm
Central Tools 3C301 – STORM™ Digital Caliper, Range: 0-6”/0-150mm
65.99
65.99
Jonard TK-120 Fiber Prep Kit Basic
Jonard TK-120 Fiber Prep Kit Basic
383.95
383.95

Kyoritsu 6514BT Digital Multifunction Tester with Bluetooth_EVSE *NEW

https://www.etisupply.com/web/image/product.template/1058334/image_1920?unique=dc15e26

2,483.00 2483.0 USD 2,483.00

Not Available For Sale

(2,483.00 / Units)

  • Brand

This combination does not exist.

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

MULTI FUNCTION INSTALLATION TESTER

KEW 6514BT

Versatile tester supporting various electrical testing for check, maintenance and troubleshooting of electrical installations.

The EVSE dedicated test function offers advanced diagnostic analysis when used with EVSE adapter.

(EVSE: Electric Vehicle Supply Equipment)

  • Offers various tests for electrical installation
    Insulation / Earth / Continuity / Motor rotation / 2-Wire Loop / RCD / Phase rotation / Frequency / AC V / SPD(Varistor)
  • Auto memory
  • Color LCD Display
  • Tests dedicated for EVSE
    Waveform check of CP signal / Latch Locking / Programmable Auto test

3D View

Video

PR

How to use ” KEW Smart Advanced App” and explaining each function.

Product Overview

Offers various tests for electrical installation

Loop 2-Wire

KEW 6514BT has an advanced measurement method called “Loop 2-Wire”. It can carry out Loop impedance test by using 2 wires only, while using 3 wires is usually required. Its small test current of 7mA does not trip even the 15mA RCDs!

Motor rotation check

Without power supply, the motor connection can be checked by electromotive force generated by spinning the three-phase motor axis (shaft) by hand or other means.

Safety lock function for insulation resistance range

This safety function prevents the unintentional voltage presence for insulation resistance range. This safety function can be set on each range by our special application.

Color LCD Display

  • All the test data is shown in one large colored screen.
  • HELP function will show how to connect the instrument according to the function selected.

Auto memory

Activating this function, KEW 6514BT automatic saves measured data at every test. Up to 1000 measured data can be saved in the internal memory.

Test can be carried out by pressing the test switch on KEW 6514BT or the switch on the remote test lead. Pressing and turning the test switch on the instrument, you can have continuous test operating.

Measured data saved in the internal memory can be transferred to PC via USB adapter (8212-USB) or Bluetooth® and it is possible to manage the measured data and print complete test report.

* 8212-USB is an optional accessory.

* Please download software from here.

Measurement Data Management app

  • "KEW Smart Advanced" application facilitates the check of any measured result on tablet or smartphone via Bluetooth®.
  • User template (xlsx format) can be uploaded to the device and the measured values are automatically entered. Using this application, KEW 6514BT allows to activate or not each function and easily change the settings such as comparator value for each function.

Dedicated function for EVSE

Offers advanced diagnostic analysis when used with optional EVSE ADAPTER

Including the followinng tests
  • Insulation
  • Volts
  • Latch switch circuit resistance
  • Earth
  • Loop 2-Wire
  • Checking CP signal
  • RCD

CP signal analysis function

Connecting KEW 6514BT to the CP terminal of the EVSE ADAPTER, CP signal can be deeply analysed as using an oscilloscope.

Also CP STATE and charge current are automatically calculated and shown on the instrument display.

Resistance measurement of latch switch circuit

Using KEW 6514BT in combination with EVSE ADAPTER KEW 8601, you can measure the circuit resistance and check if the latch switch of EVSE with type1 connector operates properly, with PASS or FAIL results.

Programmable Auto test

There is an EVSE dedicated function where you can carry out various tests. Combination and sequence of tests can be customized by using our special app.

The instrument supports you showing how to make the connections on its screen prior to test and also gives a step-by-step guide to carry out all the necessary tests.

KEW 6514BT comes complete with everything you need for testing an electrical installation


KEW 6514BTKEW 6516KEW 6516BT
VOLT600V
Continuity
Earth2-wire / 3-wire
RCDFunction×1/2, ×1, Ramp×1/2, ×1, ×5, Ramp, Auto, Uc
RCD typeAC(G)AC/A/F/B(G/S)
Test current15/30/50/100/200/500mA10/30/100/300/500/1000mA/Variable
PSC/PFC-
EVSE TestRCD
(Compatible with RCD for EVSE)
-✓(DC 6mA)
LOOP
(Compatible with RCD for EVSE)
-✓(N-PE:4mA)
Checking CP signal-
Latch switch circuit
resistance
-
Programmable Autotest-
Insulation
resintance
Test Voltage

25/50/100/125/250/

500/1000V

100/250/500/1000V
Loop ImpedanceLOOP ATT 2-wire✓(L-PE:7mA)✓(L-PE:15mA)
LOOP ATT 3-wire-
LOOP HIGH-
Phase rotation

Motor rotation check-
Auto memory-
Communication
interface
USB
Bluetooth®-

Specification

Insulation resistance

Insulation resistance

SPD (Varistor)
Test voltage25V50V100V125V250V500V1000V1000V max.
Range2.000/20.00MΩ
(Auto-ranging)
2.000/20.00/200.0MΩ
(Auto-ranging)
2.000/20.00/
200.0/1000MΩ
(Auto-ranging)
2.000/20.00/
200.0/2000MΩ
(Auto-ranging)
0 to 1000V
(goes up by 1V)
Accuracy±5%rdg±5dgt

First effective

measurement range

0.100 to 10.00MΩ

0.100 to 25.0MΩ0.100 to 50.0MΩ0.100 to 100.0MΩ0.100 to 1000MΩ

±2%rdg±2dgt

Second effective

measurement range

0.050 to 0.099MΩ

 
 
 -
 

±2%rdg±4dgt

10.01 to 18.00MΩ

25.1 to 180.0MΩ50.1 to 180.0MΩ100.1 to 900MΩ1001 to 1800MΩ
±5%rdg
Rated current1.0 to 1.2mA
0.025
0.05
0.1
0.125
0.25MΩ0.5MΩ1MΩ
Short circuit current1.5mA max

Earth

Range20.00/200.0/2000Ω (Auto-ranging)
Accuracy±2%rdg±0.08Ω (20.00Ω)
±2%rdg±3dgt (200.0/2000Ω)

Loop impedance (L-PE (2-wire))

Rated voltage85 to 260V (50/60Hz)
Impedance range200.0/2000Ω
Accuracy±3%rdg±10dgt
Measurement currentL-PE:7mA

Continuity

Range20.00/200.0/2000Ω (Auto-ranging)
Open circuit voltage (DC)7 to 14V
Measuring current200mA or more (2Ω or less)
Accuracy±2.0%rdg±8dgt

RCD

Rated voltage85 to 440V (50/60Hz)
Function

×1/2, ×1, Ramp
15/30/50/100/200/500mA
RCD typeAC(G)
AccuracyTrip
cuurent
×1/2-8 to -2%
×1+2 to +8%
Ramp-4 to +4%
Trip time×1/2±1%rdg±2ms
×1

EVSE Function

Measuring rangeVtop2.0 to 15.0V
Vbase-15.0 to -2.0V
Frequency980 to 1020Hz
Duty10.0 to 96.0%
Charging
current
6.0 to 80.0A
AccuracyVtop±4dgt
Vbase
Frequency±0.5%rdg±4dgt
Duty±10dgt
Charging
current
Depends on the accuracy of the Duty cycle.

Volts

Range300.0/600V (Auto-ranging)
Measuring rangeVolts2 to 600V
Frequency45 to 65Hz
AccuracyVolts±2%rdg±4dgt
Frequency±0.5%rdg±2dgt

Phase rotation

Measuring rangePhase rotation3 to 600V (45 to 65Hz)
Motor rotation
0.1 to 2V (1 to 10Hz)
IndicationClockwise direction: “1.2.3”and clockwise phase sequence icon
Counterclockwise direction: “3.2.1”and counterclockwise phase sequence icon

General

Applicable srandardsIEC 61010-1, IEC 61010-2-030 CAT Ⅳ 300V / CAT Ⅲ 600V Pollution degree 2
IEC 61010-2-034, IEC 61557-1,2,3,4,5,6,7,10, IEC 60529 (IP40)
Communication interfaceUSB, Bluetooth® 5.0
Power sourceLR6 (AA)(1.5V) × 8
Dimansion136(L) × 235(W) × 114(D) mm
WeightApprox. 1300g (including batteries)
Accessories7281 (Test leads with remote control switch)
7247 (Distribution board test lead)
7228A (Earth resistance test leads)
8017B (Extension prod long)
8041 (Auxiliary earth spikes [2spikes/1set])
8923 (Fuse [0.5A/600V]×1 (included), 1 (spare)
9084 (Soft case)
9142 (carrying case)
9151 (Shoulder strap)
9199 (shoulder pad)
Batteries, Instruction manual
Optional accessories7272 (Precision measurement cord set)
8212-USB (USB adapter)
8259 (Adapter fpr measurement terminal)
8601 (EVSE ADAPTER)
8602 (EVSE ADAPTER)

Please download “KEW Report2(software)” from here.

Accessories

Optional Accessories

Catalog & Document

Brand Kyoritsu