Flow Meter Calibration Procedure
To ensure you get an accurate delivery of grease, here is how to calibrate the flow meter:
- Switch on the pump.
- Press your preferred Language Button.
- Select your preferred Grease Type by pressing at the “Density” field and press “ACCEPT”.
- Set “AUTO (g)” to 100.
- Deliver the 100 grams by pressing “START”.
- Weight the amount and note it.
- Press “SETUP”.
- Press the “SET” Button under the “MODEL (#)” field.
- Input ”11111” and press “ENTER”.
- Press the “SET” Button under the “WEIGHT (mg)” field.
- Input the noted weight in milligrams, e.g. 100 g = 100000 and press “ENTER”.
- Press “X” in the right upper corner of the screen.
- Deliver 100 grams again and check that the weight is 100 +/- 3 g; otherwise repeat the calibration steps from 5.
- Repeat the steps above max. 3 times.