Hioki PW3365-20/5000Pro-10in KIT 5000A Power Logger Kit (PW3365-20 w/ 3 x CT9667-03, SF1001, Z4001, PW9002, PW3360 H-Case)

Price:

6,240.00


Fluke 393FC CAT III 1500V TRMS Wireless Clamp w/IFLEX
Fluke 393FC CAT III 1500V TRMS Wireless Clamp w/IFLEX
779.00
779.00
Mechanix SpeedKnit™ S25EP33 Cut Resistant Coated-Knit Glove w/ Reinforcement
Mechanix SpeedKnit™ S25EP33 Cut Resistant Coated-Knit Glove w/ Reinforcement
18.99
18.99

Hioki PW3365-20/5000Pro-10in KIT 5000A Power Logger Kit (PW3365-20 w/ 3 x CT9667-03, SF1001, Z4001, PW9002, PW3360 H-Case)

https://www.etisupply.com/web/image/product.template/107185/image_1920?unique=7591b27

PW3365-20/5000Pro KIT

6,240.00 6240.0 USD 6,240.00

Not Available For Sale

(0.00 / Units)

This combination does not exist.

Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

5000A Power Logger Kit PW3365-20/5000Pro Kit

Hioki Clamp On Power Meters are multi-channel power measuring devices utilizing clamp sensor input to accurately and safely measure power on single-phase to three-phase lines. The PW3365 power logger takes safety and convenience one step further by being the world's first non-metallic contact power meter that utilizes completely covered voltage clips that can be attached to any part of a cable or busbar. Customers can now monitor power demand and other power parameters to aid in energy audits and validate energy saving measures without risk of short-circuit accidents, power interruptions, or bodily injury due to electrocutions.

Key Features:

- Measure voltage from the top of the cable with zero risk of short circuit

- Supports single to three-phase, 4-wire circuits

- Measure between 90V to 520V

- Display harmonics up to the 13th order

- Slim, compact design

Specifications:

Measurement line & number of circuits50/60 Hz, Single phase 2 wires (1/2/3 circuits), Single phase 3 wires (1 circuit), Three phases 3 wires (1 circuit), Three phases 4 wires (1 circuit), Current only: 1 to 3 channels
Measurement itemsVoltage RMS, current RMS, voltage fundamental wave value, current fundamental wave value, voltage fundamental wave phase angle, current fundamental wave phase angle, frequency (U1), voltage waveform peak (absolute value), current waveform peak (absolute value), active power, reactive power (with lag/lead display), apparent power, power factor (with lag/lead display) or displacement power factor (with lag/lead display), active energy (consumption, regeneration), reactive energy (lag, lead), energy cost display, active power demand quantity (consumption, regeneration), reactive power demand quantity (lag, lead), active power demand value (consumption, regeneration), reactive power demand value (lag, lead), power factor demand, pulse input
[PW3360-21 only]: Harmonic voltage level, harmonic current level, harmonic power level, content percentage, phase angle, total harmonic distortion (THD-F or THD-R), up to 40th order
Voltage ranges600 V AC (Effective measurement range: 90.00 V to 780.00 V)
Current ranges500.00 mA to 5.0000 kA AC (depends on current sensor in use),
50.000 mA to 5.0000 A AC (Leak clamp on sensor only)
Power ranges300.00 W to 9.0000 MW (depends on voltage/current combination and measured line type)
Basic accuracyVoltage : ±0.3% rdg. ±0.1% f.s
Current : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy
Active power : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy (at power factor = 1)
Display update rate0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication)
Save destinationSD memory card, or internal memory at real time
Data save interval1 sec to 30 sec, 1 minute to 60 minutes, 14 selections
Save itemsMeasurement value save: Average only / Average, Max./Min. value, [PW3360-21 only]: Harmonic data save: Average only / average, max./min. value in binary format, Screen copy: BMP form (saved every 5 min. at minimum interval time), Waveform save: Binary waveform data
InterfacesSD/SDHC memory card
LAN 100BASE-TX: HTTP server function
USB 2.0: When connected to a PC, the SD Card and internal memory are recognized as removable storage devices, remote settings via communication program, data download
Pulse output: proportional to active power consumption when measuring integral power consumption, Isolated open-collector signal
FunctionsConnection check, Quick Set navigation guide, clock, pulse input
Power supplyAC Adapter Z1006: (100 to 240 V AC, 50/60 Hz), 40 VA (including AC adapter)
Battery Pack 9459: (DC 7.2 V, 3 VA, charging time 6 hr 10 m), 8 hours of continuous use (with back light off)
Dimensions and mass180 mm (7.09 in) W × 100 mm (3.94 in) H × 48 mm (1.89 in) D, 550 g (19.4 oz) without PW9002
180 mm (7.09 in) W × 100 mm (3.94 in) H × 67.2 mm (2.65 in) D, 830 g (29.3 oz) with PW9002
AccessoriesVoltage cord L9438-53 ×1 set, AC adapter Z1006 ×1, USB cable ×1, Instruction manual ×1, Measurement guide ×1, Color clip ×1 set: red, yellow, blue, white/two each, for color-coding clamp sensors, Spiral tubes for grouping clamp sensor cords ×5

Downloads:

Catalog

CLAMP ON POWER LOGGER PW3360

User Guide

Voltage, Current, and Power Measurement for Cycle-controlled Loads, Phase-controlled Loads, and Inverters

Manual

CLAMP ON POWER LOGGER PW3360-20,PW3360-21

Declaration of Conformity

CLAMP ON POWER LOGGER PW3360-10,PW3360-11,PW3360-20,PW3360-21,PW3360-30,PW3360-31

No Specifications