FLIR AX8 (9 Hz) 48° Thermal Imaging Camera For Continuous Condition and Safety Monitoring
AX8
Thermal Imaging Camera For Continuous Condition and Safety Monitoring
FLIR AX8 combines thermal imaging with a visual cameras in one small, affordable package for continuous temperature monitoring and alarming. The AX8 helps you guard against unplanned outages, service interruptions, and failure of electrical or mechanical equipment. Compact and easy to install, the AX8 provides continuous monitoring of electrical cabinets, process and manufacturing areas, data centers, energy generation and distribution, transportation and mass transit, storage facilities and refrigeration warehouses.
| Highlighted | |
| Ethernet Video Streaming | Yes (unauthenticated) |
| EMC | EN 61000-6-2:2001 (Immunity) EN 61000-6-3:2001 (Emission) FCC 47 CFR Part 15 Class B (Emission) |
| Thermal Sensitivity/NETD | < 0.10°C @ +30°C (+86°F) / 100 mK |
| Accuracy | ±2°C (±3.6°F) or ±2% of reading (+10 to +100°C at +10 to +35°C ambient) |
| Alarm Functions | Automatic alarms on any selected measurement function. A maximum of 5 alarms can be set |
| Alarm Output | Digital Out, store image, file sending (ftp), email (SMTP), notification |
Specifications
- IR resolution: 80 × 60 pixels
- Thermal sensitivity/NETD: < 0.10°C @ +30°C (+86°F) / 100 mK
- Field of view (FOV): 48° × 37°
- Depth of field: 0.1 m (0.33 ft.) , infinity
- Focal length: 1.54 mm (0.061 in.)
- Spatial resolution (IFOV): 11.1 mrad
- F-number: 1.1
- Image frequency: 9 Hz
- Focus: Fixed
- Detector type: Focal plane array (FPA), uncooled microbolometer
- Spectral range: 7.5–13 µm
- Detector pitch: 17 µm
- Detector time constant: Typical 12 ms
- Built-in digital camera: 640 × 480
- Digital camera, FOV: Adapts to the IR lens
- Sensitivity: Minimum 10 lux without illuminator
- Object temperature range: –10 to +150°C (14 to +302°F)
- Accuracy: ±2°C (±3.6°F) or ±2% of reading (+10 to +100°C @ +10 to +35°C ambient)
- Spotmeter: 6
- Area: 6 boxes with max./min./average
- Automatic hot/cold detection: Max./min. temperature value and position shown within box
- Measurement presets: Yes
- Atmospheric transmission correction: Automatic, based on inputs for distance, atmospheric temperature and relative humidity
- Optics transmission correction: Automatic, based on signals from internal sensors
- Emissivity correction: Variable from 0.01 to 1.0
- Reflected apparent temperature correction: Automatic, based on input of reflected temperature
- External optics/windows correction: Automatic, based on input of optics/window transmission and temperature
- Measurement corrections: Global object parameters
- Alarm functions: Automatic alarms on any selected measurement function. A maximum of 5 alarms can be set.
- Alarm output: Digital out, store image, file sending (FTP), email (SMTP), notification
- Color palettes: Arctic Gray Iron Lava Rainbow Rainbow HC
- Set-up commands: Date/time, Temperature (°C/°F)
- Web interface: Yes
- Storage media: Built-in memory for image storage
- Image storage mode: IR, visual, MSX
- File formats: JPEG + FFF
- Image streaming formats: Motion JPEG stream MJPEG Baseline Process Encoder Baseline ISO/IEC 10918-1 JPEG compliance MPEG stream Stream format MPEG-4 ISO/IEC 14496-2 Simple Profile level 2 H.264 stream Stream format H.264 Baseline Profile level 2.0
- Image streaming resolution: 640 × 480
- Image modes: Thermal Visual MSX
- Automatic image adjustment: Continuous
- Multi Spectral Dynamic Imaging ( MSX ): IR image with enhanced detail presentation
- Ethernet: Control, result and image
- Ethernet, type: 100 Mbps
- Ethernet, standard: IEEE 802.3
- Ethernet, connector type: M12 8-pin FLIR X-Coded (Adapter needed to standard X-Coded Part # T129886ACC)
- Ethernet, communication: TCP/IP socket-based FLIR proprietary
- Ethernet, video streaming: Yes
- Ethernet, power: Power over Ethernet, PoE IEEE 802.3af class 2.
- Ethernet, protocols: Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, sftp, SMTP, DHCP, MDNS (Bonjour)
- Digital input, purpose: NUC, NUC disable, Alarm
- Digital input: 1 opto-isolated, 10–25 VDC
- Digital output, purpose: As function of alarm, output to ext. device (programmatically set)
- Digital output: 1 opto-isolated, 10–25 VDC, max. 0,6 A
- Digital I/O, isolation voltage: 500 VRMS
- Digital I/O, supply voltage: 10-25 VDC, max. 200 mA
- Digital I/O, connector type: M12 8-pin A-coded (shared with ext. power)
- External power operation: 12/24 VDC, 2 W continuously/ 4.7 W absolute max
- External power, connector type: M12 8-pin A-coded (Shared with digital I/O)
- Voltage: Allowed range 10.8–30 VDC
- Power supply rating: Class 2 / LPS
- Operating temperature range: –10°C to +50°C (+14°F to +122°F)
- Storage temperature range: –40°C to +70°C (–40°F to +158°F) according to IEC 68-2-1 and IEC 68-2-2
- Humidity (operating and storage): IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F) / 2 cycles
- EMC: EN 61000-6-2:2001 (Immunity) EN 61000-6-3:2001 (Emission) FCC 47 CFR Part 15 Class B (Emission)
- Encapsulation: IP 67 (IEC 60529)
- Bump: 25 g (IEC 60068-2-29)
- Vibration: 2 g (IEC 60068-2-6)
- Declaration of conformity: See: https://support.flir.com/resources/DoC
- Weight: 0.125 kg (0.28 lb.)
- Camera size (L × W × H): 54 × 25 × 79 mm (2.1 × 1 × 3.1 in.) without connectors 54 × 25 × 95 mm (2.1 × 1 × 3.7 in.) with connectors
- Base mounting: 4× mounting hole depth max 4.8 mm for screw type Delta PT 22 (ø2.2 mm)
- Housing material: PA6 with 30% GF (glass fiber reinforced)
- Packaging, type: Cardboard box
- List of contents: Infrared camera with lens Cardboard box Printed documentation
- Packaging, weight: 0.48 kg (1.06 lb.)
- Packaging, size: 210 × 142 × 70 mm (8.27 × 5.59 × 2.76 in.)
- EAN-13: 4743254001725
- UPC-12: 845188009373
- Country of origin: Estonia
| Brand | Flir |