Fluke 115 Field Technicians Digital Multimeter w/CAL TRACEABLE W DATA (FLUKE-115 CAL)
SKU: 5160536 | FLUKE-115 CAL
- Compact True-rms digital multimeter for field service
- Includes: meter, holster, 4 mm PVC-Insulated test lead
- Easy one-handed operation of the meter
- Min/Max/Average to record signal fluctuations
What's in the box:
- Holster
- Installed 9V battery
- 4 mm PVC-Insulated test lead
- User manual
- A traceable certificate of calibration with data from Fluke
Fluke 115 Field Technicians Digital Multimeter w/CAL TRACEABLE W DATA (FLUKE-115 CAL)
Details
Compact true-rms meter for field service technicians
The Fluke 115 field technician’s digital multimeter measures True-rms voltage and current with plus resistance, continuity, frequency, and capacitance to meet the needs of a wide variety of field service technicians.
The 115 digital multimeter offers the users one-handed operation and a backlit display. The large, easy-to-read digits offer a 6000-count resolution. The 115 provides Min/Max/Average with elapsed time to record signal fluctuations. It also measures:
- AC and DC voltage to 600V,
- AC and DC current to 10 A (20 A overload for 30-seconds max).
For a complete comparison of specifications, please visit our selection guide for digital multimeters.
| Fluke 115 Field Technicians Digital Multimeter | Fluke 117 Electrician's Multimeter | Fluke 177 True-RMS Digital Multimeter | Fluke 233 Remote Display Digital Multimeter | Fluke 3000 FC Series Wireless Multimeter | |
|---|---|---|---|---|---|
| CAT rating | CAT III 600 V | CAT III 600 V | CAT III 1000 V CAT IV 600 V | CAT III 1000 V CAT IV 600 V | CAT III 1000 V CAT IV 600 V |
| True-rms readings | ✔ | ✔ | ✔ | ✔ | ✔ |
| Voltage AC/DC | 600 V | 600 V | 1000 V | 1000 V | 1000 V |
| Current AC/DC | 10 A | 10 A | 10 A | 10 A | 400 mA |
| Resistance | 40 MΩ | 40 MΩ | 50 MΩ | 40 MΩ | 50 MΩ |
| Capacitance | 9,999 μF | 9,999 μF | 9,999 μF | 9,999 μF | 9,999 μF |
| Temperature | -40 °C to 400 °F | -40 °C to 400 °F | -40 °C to 400 °F | -40 °C to 400 °F | with t3000 FC |
| Additional measurement capabilities | Continuity/diode test | Continuity/diode test, frequency, non-contact voltage detection | Continuity/diode test, frequency, low input impedance | Continuity/diode test, frequency | Frequency, continuity/diode test. Able to connect to three 3000 FC modules. |
What's in the box:
- Digital multimeter
- Holster
- Installed 9V battery
- 4 mm PVC-Insulated test lead
- Quick Reference Guide
Key Features
- Compact True-rms digital multimeter for field service
- Includes: meter, holster, 4 mm PVC-Insulated test lead
- Easy one-handed operation of the meter
- Min/Max/Average to record signal fluctuations
Specifications
Accuracy Specifications
- DC millivolts - Range/resolution: 600.0 mV / 0.1 mV
- DC millivolts - Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
- DC volts - Range/resolution: 6.000 V / 0.001 V; 60.00 V / 0.01 V; 600.0 V / 0.1 V
- DC volts - Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
- AC millivolts 1 True RMS - Range/resolution: 600.0 mV / 0.1 mV
- AC millivolts 1 True RMS - Accuracy: 1.0% + 3 (DC, 45 Hz to 500 Hz); 2.0% + 3 (500 Hz to 1 kHz)
- AC volts 1 True RMS - Range/resolution: 6.000 V / 0.001 V; 60.00 V / 0.01 V; 600.0 V / 0.1 V
- AC volts 1 True RMS - Accuracy: 1.0% + 3 (DC, 45 Hz to 500 Hz); 2.0% + 3 (500 Hz to 1 kHz)
- Continuity - Range/resolution: 600 Ω / 1 Ω
- Continuity - Accuracy: Beeper on 250 Ω detects opens or shorts of; 500 μs or longer.
- Ohms - Range/resolution: 600.0 Ω / 0.1 Ω; 6.000 kΩ / 0.001 kΩ; 60.00 kΩ / 0.01 kΩ; 600.0 kΩ / 0.1 kΩ; 6.000 MΩ / 0.001 MΩ
- Ohms - Accuracy: 0.9% + 1
- Ohms - Range/resolution: 40.00 MΩ / 0.01 MΩ
- Ohms - Accuracy: 5% + 2
- Diode test - Range/resolution: 2.00 V / 0.001 V
- Diode test - Accuracy: 0.9% + 2
- Capacitance - Range/resolution: 1000 nF / 1 nF; 10.00 μF / 0.01 μF; 100.0 μF / 0.1 μF; 9999 μF / 1 μF; 100 μF to 1000 μF
- Capacitance - Accuracy: 1.9% + 2
- Capacitance - Range/resolution: > 1000 μF
- Capacitance - Accuracy: 5% + 20%
- Lo-Z capacitance - Range: 1 nF to 500 μF
- Lo-Z capacitance - Accuracy: 10% + 2 typical
- AC amps True RMS (45 Hz to 500Hz) - Range/resolution: 6.000 A / 0.001 A; 10.00 A / 0.01 A
- AC amps True RMS (45 Hz to 500Hz) - Accuracy: 1.5% + 3; 20 A overload for 30-seconds max
- DC amps - Range/resolution: 6.000 A / 0.001 A; 10.00 A / 0.01 A
- DC amps - Accuracy: 1.0% + 3; 20 A overload for 30-seconds max
- Hz (V or A input) 2 - Range/resolution: 99.99 Hz / 0.01 Hz; 999.9 Hz / 0.01 Hz; 9.999 kHz / 0.001 kHz; 50.00 kHz / 0.01 kHz
- Hz (V or A input) 2 - Accuracy: 0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 2. Temperature Range/Resolution: -40℉ to 752℉ / 0.2℉.
General Specifications
- Maximum voltage between any terminal and earth ground: 600 V
- Safety: IEC 61010-1: Pollution Degree 2; IEC 61010-2-033: CAT III 600V
- Display: Digital: 6,000 counts, updates 4 per second
- Bar graph: 33 segments, updates 32 per second
- Operating temperature: -10℃ to + 50℃
- Storage temperature: -40℃ to + 60℃
- Battery type: 9 volt Alkaline, IEC 6LR61
- Battery life: 400 hours typical, without backlight
- Size: 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
- Weight: 550 g
- Warranty: 3 years
Additional Information
| Brand | Fluke |