Fluke 80I-2010S 2,000A AC/DC CURRENT CLAMP

Price:

$ 1,359.99


Fluke 323 True RMS Clamp Meter (FLUKE-323)
Fluke 323 True RMS Clamp Meter (FLUKE-323)
$ 187.19
$ 207.99 (10% OFF)
Fluke 80PJ-1 TYPE J BEAD PROBE,THERMOCOUPLE ASSEMBLY,TYPE J,BEADED,TYPE J,BULK
Fluke 80PJ-1 TYPE J BEAD PROBE,THERMOCOUPLE ASSEMBLY,TYPE J,BEADED,TYPE J,BULK
$ 44.99
$ 49.99 (10% OFF)

Fluke 80I-2010S 2,000A AC/DC CURRENT CLAMP

https://www.etisupply.com/web/image/product.template/24525/image_1920?unique=cb16f0d

SKU: 5125579 | 80i-2010s

  • Conveniently measure current without having to disconnect the load
  • 2,000A AC and DC current clamp
  • Maximum conductor size – 52mm (2.05in)
  • Maximum opening – 81.5mm (3.2in)

What's in the box:

  • One Fluke 80i-2010s AC/DC Current Clamp

$ 1,359.99 1359.99 USD $ 1,359.99

Not Available For Sale

($ 0.00 / Units)

  • Brand

This combination does not exist.

CAT III 1000 V CAT IV 600 V Current Clamps IP40

 
Terms and Conditions

Product images shown are for illustration purposes only and may not be an exact representation of the product.

Fluke

80i-2010s

Fluke 80I-2010S 2,000A AC/DC CURRENT CLAMP

Details

Available in packs of one, or as a three pack the Fluke 80i-2010s allows you to measure up to 2,000A AC and/or DC on large conductors with 0.8% accuracy. The 80i-2010S provides a convenient way to measure current without having to disconnect the load.

Key Features

  • Conveniently measure current without having to disconnect the load
  • 2,000A AC and DC current clamp
  • Maximum conductor size – 52mm (2.05in)
  • Maximum opening – 81.5mm (3.2in)

Specifications

General Specifications

  • Modules: 80i-2010s
  • Dimensions: 110 mm x 270 mm x 46mm
  • Weight: 0.710 kg (1.6 lbs), including battery
  • Output Cable: 1.5 m (60 in) Shielded Coaxial cable with BNC plug
  • Maximum Conductor Size: 52.0 mm (2.05 in)
  • Maximum Jaw Opening: 81.5 mm
  • Output to Zero: Auto adjustment with Zero button
  • Temperature Operating: -10 °C to 50 °C (14 °F to 122 °F)
  • Storage (battery removed): -30 °C to +60 °C (-22 °F to +140 °F)
  • Operating Humidity: ≤ 90 % RH (at 10 °C to 30 °C) ≤ 75 % RH (at 30 °C to 40 °C) ≤ 45 % RH (at 40 °C to 50 °C)
  • Operating Altitude: 2,000 m (6560 ft)
  • Storage Altitude: 12,000 m (40,000 ft)
  • Demagnetize Clamp: Open and close the Clamp jaws several times with soft click, use of the clamp on uninsulated conductors is limited to 1000 Vac rms or DC and frequencies 1 kHz or less.
  • Safety: IEC 61010-1, Pollution Degree 2, IEC 61010-2-032: CAT III 1000 V /CAT IV 600 V
  • Ingress Protection: IEC 60529, IP40
  • Power Supply Type: 2 x AA alkaline battery, IEC LR6
  • Battery Life: 150 hours (typically)
  • Low battery indicator: Yes

Electrical Specifications

  • Current Range: 2000 A ac rms, ± 2000 A dc
  • Output Sensitivity: 01 mV/A
  • Accuracy: ± 0.8 % of reading ± 0.2 % of range
  • Bandwidth for Accuracy Specification: DC to 400 Hz
  • Load impedance: >1 MΩ and <10 pF
  • Frequency Response (small signal): DC to 20 kHz (-3 dB)
  • Temperature Coefficient: 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
  • Working Voltage: 1000 V AC RMS or DC

Additional specifications

  • Part #: 5125579
  • UPC: 0 95969 91877 0
  • Weight: 1.6 lb (0.710 kg)

Additional Information



Brand Fluke
80i-2010s-Instruction-Sheet-FLK_5125579.pdf