Fluke i3000 Flex AC Current Clamp, 4 Pack
SKU: 2696367 | i3000 Flex 4PK
- Three ranges 30 A
- 300 A
- 3000 A, 1, 10 or 100 mV/A output
- Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
- Maximum conductor diameter 178 mm (7 in)
- CAT III 600 V safety rating
Fluke i3000 Flex AC Current Clamp, 4 Pack
Details
The i3000s Flex is an AC current clamp utilizing the Rogowski principle. It can be used to measure currents up to 3000 A when used in conjunction with oscilloscopes, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.
Key Features
- Three ranges 30 A
- 300 A
- 3000 A, 1, 10 or 100 mV/A output
- Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
- Maximum conductor diameter 178 mm (7 in)
- CAT III 600 V safety rating
Specifications
Electrical Specifications
- Current ranges: 30 A
300 A
3000 A
AC rms
- Output sensitivity (AC-coupled): 100 mV
10 m
1 mV per A
- Load impedance: 100 kΩ minimum
- Accuracy: at +25°C
±1% of range (45 Hz to 65 Hz)
- Linearity: 10% to 100% of range
±0.2% of reading
- Noise: 8 mV AC rms (30 A)
2 mV AC rms (300 A, 3000 A)
- Frequency range: 10 Hz to 50 kHz (-3 dB)
- Phase error: < ±1° (45 Hz to 65 Hz)
±10° (at 20 kHz)
- Position sensitivity (with cable > 25 mm from the coupling): Position sensitivity: From 1% up to 3% of range with cable, depending on distance from the center (see figure left). Measurements closer than 25 mm from the coupling are typically greater than 3% of range.; External wire influence: 1% (-40 db) of external current >200 mm from head.
±2% of range
- External field: with cable > 200 mm from the head
±1% of range
- Power supply: 2 x AA/MN 1500/LR6 Alkaline, 400 hours, low battery indicator
- Temperature coefficient: ±0.08% of reading per °C
- Working voltage: see safety standards section
600 V AC rms or DC
General Specifications
- Head circumference: 610 mm (24in)
- Head cable diameter: 14.3 mm (0.56in)
- Head bend radius: 38.1 mm (1.5in)
- Cable length (head to electronics): 2 m (6.56 ft)
- Output connection: 0.5 m cable terminated with safety BNC connector. Supplied with 4mm safety plug adapter
- Operating temperature range: -20°C to +90°C (-4°F to 190°F) (head)
-20°C to +85°C (-4°F to 185°F) (electronics)
- Strong temperature range: -40°C to +105°C (-40°F to 221°F) (head)
-20°C to +85°C (-4°F to 185°F) (electronics)
- Operating humidity: 15% to 85% (non-condensing)
- Weight: 180 g (0.396 lb) (head)
190 g (0.419 lb) (electronics)
- Safety standards: BS EN 61010-1: 2001
BS EN 61010-2-032: 2002
BS EN 61010-031: 2002
600 Vrms, Category III, Pollution Degree 2
Use of the probe on uninsulated conductors is limited to 600 V AC rms or DC and frequencies below 1 kHz
- EMC standards: EN 61326: 1998 +A1, A2, and A3
- Head cable length (double insulated): 610 mm or 914 mm, depending on model
Additional specifications
- Part #: 2696367
- UPC: 0 95969 36247 4