Amprobe HD110C IP67 Heavy Duty Multimeter
SKU: FLK_2670779 | 2670779
2670779
Fluke Amprobe HD110C IP67 Heavy Duty Multimeter
Specifications
- Model: Fluke 2670779
- Part #: 2670779
- FEATURE — HD110C: HD160C
- DC Voltage — 200.0 mV, 2.000 V, 20.00 V, 200.0 V, 1500 V: 1000.0 mV, 10.000 V, 100.00 V, 1500.0 V
- AC Voltage — 200.0 mV, 2.000 V, 20.00 V, 200.0 V, 1000 V: 1000.0 mV, 10.000 V, 100.00 V, 1000.0 V
- Current — AC/DC 200.0 µA, 2.000 mA, 20.00 mA, 200.0 mA, 2 A: 100.00 µA, 1000.0 µA, 10.000 mA, 100.00 mA, 400.0 mA, 2.000 A
- Resistance — 200.0 O, 2.000 kO, 20.00 kO, 200.0 kO, 2.000 MO, 20.00 MO: 1000.0 O, 10.00 kO, 100.00 kO, 1000.0 kO, 10.000 MO, 40.00 MO
- Diode — •: –
- Continuity: •
- Frequency — –: 100.00 Hz, 1000.0 Hz, 10.000 kHz, 100.00 kHz, 1000.0 kHz, 10.000 M Hz
- Capacitance — –: 40.00 nF, 400.0 nF, 4.000 µF, 40.00 µF, 400.0 µF
- Temperature — –: -4 °F → 2372 °F (-20 °C → 1300°C)
- True-rms — –: •
- DC Volts range:: 200 mV, 2 V, 20 V, 200 V, 1500 V
- DC Volts resolution:: 0.1 mV
- DC Volts accuracy:: All ranges ±(0.1 % rdg+2 dgts)
- DC Volts input impedance:: 10 MO
- DC Volts OL protection:: >1500 V DC/1000 V AC rms
- DC Volts transient protection:: >12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV
- AC Volts (45 Hz to 2 kHz) ranges:: 200 mV, 2 V, 20 V, 200 V, 1000 V
- AC Volts (45 Hz to 2 kHz) resolution:: 0.1 mV
- AC Volts (45 Hz to 2 kHz) accuracy:: 200 mV to 200 V (45-500 Hz) ±(0.8 % rdg+4 dgts),
- AC Volts (45 Hz to 2 kHz) accuracy:: 200 mV to 200 V (500 Hz-2 kHz) ±(1.5 % rdg+5 dgts)
- AC Volts (45 Hz to 2 kHz) accuracy:: 1000 V (50-60 Hz) ±(0.8 % rdg+4 dgts)
- AC Volts (45 Hz to 2 kHz) accuracy:: 1000 V (60-500 Hz) ±(1.5 % rdg+5 dgts)
- AC Volts (45 Hz to 2 kHz) input impedance:: 10 MO
- AC Volts (45 Hz to 2 kHz) OL protection:: 1500 V DC/1000 V AC rms
- AC Volts (45 Hz to 2 kHz) transient protection:: 12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV.
- DC Current range:: 200 µA, 2 mA, 20 mA, 200 mA, 2 A
- DC Current resolution:: 0.1 µA
- DC Current accuracy:: 200 µA to 20 mA ±(0.5 % rdg+2 dgts)
- DC Current accuracy:: 200 mA to 2 A ±(1.0 % rdg+2 dgts)
Additional Information
| Brand | Amprobe |