  • Current Range: 0.1 to 100A DC or 0.1 to 100A AC
  • Basic Accuracy (DC to 1kHz): 100mV/A setting: 50mA to 10A +/- 3% of reading + 50mA 10mV/A setting: 50mA to 40A +/- 4% of reading + 50mA 40A to 80A +/- 12% of reading + 50mA 80 to 100A +/- 15% of reading
  • Output Signal: 10A range: 100mV/A | 100A range: 10mV/A
  • Bandwidth: 1Hz to 20kHz
  • Working Voltage: 600V AC rms
  • Maximum Conductor Size: 11.8 mm (.46 inch) diameter
  • Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V

$ 1,110.37 1110.366 USD $ 1,233.74

Not Available For Sale

($ 0.00 / Units)

  • Brand

This combination does not exist.

Current Clamps Probes

 
Terms and Conditions

Product images shown are for illustration purposes only and may not be an exact representation of the product.

Fluke

80i 110s

Fluke 80I AC/DC Current Probe (Fluke 80I-110S)

Details

The 80I-110s is compatible with any Fluke ScopeMeter Test Tool, Power Harmonics Analyzer, Oscilloscope, Multimeter, or other voltage measurement device that has the following features: BNC input connectors or if using a meter convert the banana plugs to a BNC connector using the adapter PM9081/001.

Useful resources and rugged tools for Solar professionals

Key Features

  • Current Range: 0.1 to 100A DC or 0.1 to 100A AC
  • Basic Accuracy (DC to 1kHz): 100mV/A setting: 50mA to 10A +/- 3% of reading + 50mA 10mV/A setting: 50mA to 40A +/- 4% of reading + 50mA 40A to 80A +/- 12% of reading + 50mA 80 to 100A +/- 15% of reading
  • Output Signal: 10A range: 100mV/A | 100A range: 10mV/A
  • Bandwidth: 1Hz to 20kHz
  • Working Voltage: 600V AC rms
  • Maximum Conductor Size: 11.8 mm (.46 inch) diameter
  • Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V

Specifications

  • Nominal current range: 10 A, AC/DC

100 A, AC/DC

  • Continuous current range: 0.1 A - 10 A AC/DC

1 A - 100 A AC/DC

  • Maximum non-destructive current: 140 A - 2 kHz
  • Lowest measurable current: 0.1 A
  • Basic accuracy: 100 mV/A setting: 50 mA to 10 A ±3% of reading +50 mA

10 mV/A setting: 50 mA to 40 A ±4% of reading +50 mA

40 A to 80 A ±12% of reading +50 mA

80 to 100 A ±15% of reading

  • Useable frequency: DC - 100 kHz
  • Output level(s): 10 A range: 100 mV/A

100 A range: 10 mV/A

  • Zero error adjustment: Yes

Safety Specifications

  • Safety: CAT II, 600 V

CAT III, 300 V

  • Maximum voltage: 600 V

Mechanical and General Specifications

  • Warranty: 1 year
  • Battery life: 9 V, 55 h
  • Maximum conductor diameter: 11.8 mm
  • Output cable length: 1.6 m
  • BNC adapter: Yes