Eaton 190633 FAZ-C7/2-NA-L Miniature circuit breaker (MCB), 7 A, 2p, characteristic: C, NA, labelling
General specifications
Product NameEaton Moeller series xEffect - FAZ-NA, FAZ-RT MCBCatalog Number190633Model CodeFAZ-C7/2-NA-LEAN4015081930449Product Length/Depth105 mmProduct Height75.5 mmProduct Width35.4 mmProduct Weight0.242 kgCompliancesRoHS conformCertificationsCSA-C22.2 No. 5-09
CSA (Class No. 1432-01)
UL (File No. E235139)
IEC/EN 60947-2
IEC 60947-2
UL 489
CSA (File No. 204453)
UL 489, CSA C22.2 No. 5
Specially designed for North America, suitable as BCPD
North America (UL listed, CSA certified)
CE marking
UL (Category Control Number DIVQ)
Product specifications
Used withMiniature circuit breaker
FAZ-NAType
- FAZ-NA
- Miniature circuit breaker
Special featuresAmbient temperature hint: a 1 °C increase results in a 0.5% linear reduction of current carrying capacityApplication
- Feeder circuits, branch circuits
- Switchgear for export to North America (UL-listed)
- xEffect - Switchgear for industrial and advanced commercial applications
Amperage Rating7 AVoltage rating240 V AC / 415 V ACFeaturesAdditional equipment possible10.11 Short-circuit ratingIs the panel builder's responsibility. The specifications for the switchgear must be observed.10.12 Electromagnetic compatibilityIs the panel builder's responsibility. The specifications for the switchgear must be observed.10.13 Mechanical functionThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.10.2.2 Corrosion resistanceMeets the product standard's requirements.10.2.3.1 Verification of thermal stability of enclosuresMeets the product standard's requirements.10.2.3.2 Verification of resistance of insulating materials to normal heatMeets the product standard's requirements.10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effectsMeets the product standard's requirements.10.2.4 Resistance to ultra-violet (UV) radiationMeets the product standard's requirements.10.2.5 LiftingDoes not apply, since the entire switchgear needs to be evaluated.10.2.6 Mechanical impactDoes not apply, since the entire switchgear needs to be evaluated.10.2.7 InscriptionsMeets the product standard's requirements.10.3 Degree of protection of assembliesDoes not apply, since the entire switchgear needs to be evaluated.10.4 Clearances and creepage distancesMeets the product standard's requirements.10.5 Protection against electric shockDoes not apply, since the entire switchgear needs to be evaluated.10.6 Incorporation of switching devices and componentsDoes not apply, since the entire switchgear needs to be evaluated.10.7 Internal electrical circuits and connectionsIs the panel builder's responsibility.10.8 Connections for external conductorsIs the panel builder's responsibility.10.9.2 Power-frequency electric strengthIs the panel builder's responsibility.10.9.3 Impulse withstand voltageIs the panel builder's responsibility.10.9.4 Testing of enclosures made of insulating materialIs the panel builder's responsibility.Frame45 mmPollution degree2Mounting MethodIEC/EN 60715 top-hat railDegree of protectionIP20 (IEC)
UL/CSA Type: -
IP20
IP40 (when fitted)Rated impulse withstand voltage (Uimp)4 kVTerminal protectionFinger and hand touch safe, DGUV VS3, EN 50274Terminals (top and bottom)Twin-purpose terminalsTripping characteristicCAmbient operating temperature - max75 °CAmbient operating temperature - min-25 °CBuilt-in depth60 mmConnectable conductor cross section (multi-wired) - max25 mm²Connectable conductor cross section (multi-wired) - min1 mm²Connectable conductor cross section (solid-core) - max25 mm²Connectable conductor cross section (solid-core) - min1 mm²Current limiting class3Enclosure width105 mmFrequency rating - max60 HzFrequency rating - min50 HzHeat dissipation capacity0 WHeat dissipation per pole, current-dependent0 WDirection of incoming supplyAs requiredWidth in number of modular spacings2Voltage rating (IEC/EN 60947-2)
- 254 V AC / 440 V AC
- 480Y V AC / 277 V AC (UL)
Voltage rating at DC60 V DCVoltage typeACMounting positionAs requiredOvervoltage categoryIIINumber of polesTwo-poleFunctionsCurrent limiting circuit breakerLifespan, electrical20000 operationsRelease characteristicCMounting width17.7 mmSelectivity class3Mounting width per pole17.7 mmNumber of poles (protected)2Number of poles (total)2Operational switching capacity7.5 kARated insulation voltage (Ui)440 VRated operational current for specified heat dissipation (In)7 ARated operational voltage (Ue) - max240 VRated short-circuit breaking capacity (EN 60898) at 230 V15 kARated short-circuit breaking capacity (EN 60898) at 400 V15 kARated short-circuit breaking capacity (IEC 60947-2) at 230 V10 kARated short-circuit breaking capacity (IEC 60947-2) at 400 V14 kARated switching capacity (IEC/EN 60947-2)15 kAStatic heat dissipation, non-current-dependent0 WSuitable forFlush-mounted installationTerminal capacity (control cable)25 mm² (1x)Terminal capacity of screw terminals for main cable10 mm² (2x)Tightening torqueUL: 4 Nm (36 lb-in) for AWG 6
Max. 2.4 Nm
UL: 2.4 Nm (21 lb-in) for AWG 18 - AWG 12
UL: 2.8 Nm (25 lb-in) for AWG 10 - AWG 8